Vario Photometer II
DP 310

The Vario Photometer II DP 310 is suitable for on-site measurement of a range of parameters for various areas of application:
- general practice and naturopathy
- sports medicine, training management
- rehabilitation
- emergency and intensive care wards
- fitness studios 
- for countries with extensive rural areas, with low population density or an 
  infrastructure which is only developed to a limited extent
- veterinary medicine
- training observation in equitation

The device is ready for use immediately after switching on, calibration is not required. All filters are installed, and you only need to select the parameter to start the measurement.

The device saves all measured values and is suitable for use as a portable device with its low weight. Testing is very simple with only a small drop of blood required.

Do you need further information?
Take up contact to us, we advise you gladly.
Email: info@diaglobal.de
Tel.: +49 (0)30 6576 2597


Travelling with the Vario Photometer II:  Vario II mobile laboratory
Measured parameters:

ALAT/GPT* GPT 442
ASAT/GOT* GOT 442
cholesterol CHO 142
HDL cholesterol HDL 321
creatine kinase / serum* CK 321
creatine kinase / blood* CK 121
erythrocytes ERY 142
glucose GLU 142
haemoglobin SLS HB 342
haematocrit HCT 142
kreatinin* KRE 121
lactate LAC 142
lactate rapid LAC 342
triglycerides TRI 142
urea HST 321
* dry block heater additionally required

Software for training control
For an evaluation of the measured lactate values, we recommend the software program of our cooperation partner Prof. Dr. med. Kai Röcker, University Hospital Freiburg, Abt. Preventive and Rehabilitative Sports Medicine 
 www.ergonizer.de Ergonizer is an innovative computer program for endurance performance diagnostics and analysis of stress tests, developed in the university environment. For more than 20 years, the software is continuously adapted to the latest user interfaces and offers an optimum of user-friendliness and information gain. Basic use of the software is the graphical interpretation and stable diagnostic evaluation of lactate curves.

The Diaglobal photometers are also compatible with software programs of other providers, for instance Mesics.
 www.mesics.de

Vario photometer
Size: 195x100x45 mm
Weight: 0.4 kg
Wavelengths: 520 / 365 nm
RS232C interface
Mains or battery-operated




   
Dry block heater DZ 003
Required for the
measurement of
– ALAT/GPT
– ASAT/GOT
– CK-NAC
– Creatinine
Size: 156 x 96 x 72 mm
Weight: 1 kg
For 12 round cuvettes for incubation at 37 °C
   Top Top